Optica XT in Action
Renal Monohydrate Stone
Renal Stone by Dr. Richard Vanlangendonck
12 Bladder Stones
Laser for Stones and Soft Tissues
The Optica XT Thulium Fiber Laser system and its associated accessories are designed for use in the treatment of bladder stones, ureter/renal stones, BPH, tumors and all applicable soft tissues. 1940 nm wavelength is highly absorbed by water making it an ideal choice for surgical based application.
Indications
Urology
- Ablation of Benign Prostatic Hyperplasia (Hypertrophy) [BPH]
- Laser Resection of the Prostrate (LRP)
- Laser Enucleation of the Prostate (LEP)
- Laser Ablation of the Prostate (LAP)
- Transurethral Incision of the Prostate (TUIP)
- Condylomas
- Urethral strictures
- Lesions of external genitalia
- Bladder neck incisions (BNI)
- Ablation and resection of bladder tumors, urethral tumors, and ureteral tumors
- Endoscopic fragmentation of urethral, ureteral, bladder, and renal calculi
- Treatment of distal impacted fragments remaining in the ureters following lithotripsy
Lithotripsy and Percutaneous Urinary Lithotripsy Indications
- Endoscopic fragmentation of urethral, ureteral, bladder and renal calculi including cystine, calcium oxalate, monohydrate and calcium oxalate dehydrate stones
- Endoscopic fragmentation of renal calculi
- Treatment of distal impacted fragments of steinstrasse when guide wire cannot be passed
Gastroenterology
Open and endoscopic gastroenterology surgery (incision, excision, resection, ablation, vaporization, coagulation and haemostasis) including:
- Appendectomy
- Polyps
- Biopsy
- Gall Bladder calculi
- Biliary/Bile duct calculi
- Ulcers
- Gastric ulcers
- Duodenal ulcers
- Non Bleeding Ulcers
- Pancreatitis
- Haemorrhoids
- Cholecystectomy
- Benign and Malignant Neoplasm
- Angiodysplasia
- Colorectal cancer
- Telangiectasias
- Telangiectasias of the Osler-Weber-Renu disease
- Vascular Malformation
- Gastritis
- Esophagitis
- Esophageal ulcers
- Varices
- Colitis
- Mallory-Weiss tear
- Gastric Erosions
Gynecology
Open and laparoscopic gynecological surgery (incision, excision, resection, ablation, vaporization, coagulation and hemostasis) of soft tissue.
Features and Benefits
Specifications
Laser Type | Thulium Fiber Laser |
Wavelength | 1940nm |
Modes | Pulse and SuperPulse |
Maximum Average Power | 60 W |
Visible Aiming Beam | 532nm (green) |
Cooling System | Self-contained air cooled |
Operating Temperature | 65 - 77° F (18-25° C) |
Electrical Requirements | 100 - 240 VAC, 15 - 7.5 A, 50/60 Hz |
Dimensions | 24” L x 20” W x 16” H |
Weight | 95 lbs (43 kg) |
Safety Compliance | CAN/CSA-C22.2 60601, IEC 60825, IEC 60601-1,3.1 Edition, IEC60601-1-2, IEC 60601-1-6: 2010, IEC60601-2-22, IEC62304, IEC60601-1-9 |
Warranty | One year, parts and labor |
Features and specifications subject to change without prior notice.
Clinical Feedback
Coming soon...
Frequently Asked Questions
Frequently Asked Questions
Q Why should I buy the Optica XT over the competition's product?
A The Optica XT uses the latest thulium fiber laser technology to deliver a more efficient laser at a very competitive price. Convergent has been a market leader in stone and soft tissue laser systems since 1995; we have proven our capability to design, manufacture, and support our laser systems.
Q What features set the Optica XT apart from its competition?
A The Optica XT offers compact and efficient design, ease-of-use, and top-quality fiber-optics.
Q I'm under the impression that lasers are difficult and expensive to maintain. How reliable is the Optica XT laser?
A The Optica XT was designed for reliability and serviceability. Under normal operating conditions, the laser should last many years with minimal service needs. However, we do recommend a preventive maintenance check-up at 12 month intervals depending on the operating environment and frequency of use.
Q If I'm planning to use the Optica XT in an office-based environment, do I need any special personnel to operate and maintain the Optica XT? What if the laser system stops working?
A Convergent provides in-service training with each new Optica XT laser system purchase. The in-service training is designed to provide adequate information to each participant. After completion of the training program, each participant will be familiar with basic troubleshooting procedures and be able to comfortably operate the laser system. Additionally, the Optica XT performs self-diagnostics and will inform the operator when it detects any condition that is out of the ordinary. The Optica XT comes with a one-year parts and labor warranty. Extended warranties are available.
Q Is the Optica XT available for sale outside of the U.S.?
A Please contact our sales department at This email address is being protected from spambots. You need JavaScript enabled to view it.
Q Do I need any special electrical utilities to operate the Optica XT laser?
A The Optica XT can operate from a U.S. standard 110 - 240 VAC, 15 - 7.5 A, 50/60Hz.